| Abstract Scope |
Nuclear grade graphite is a critical structural and moderating material for advanced reactors, where components must perform under elevated temperature, stress, oxidation, and irradiation. Because graphite is brittle and flaw sensitive, measured tensile strength is dependent on specimen geometry, stressed volume, and microstructural variability. This work evaluates Weibull size effects in nuclear graphite using modified ASTM C749 dogbone specimens across multiple sizes and geometries. Completed size effect testing of grade 2114 graphite is presented, along with initial NBG-18 testing for comparison with a coarse grained nuclear graphite. Digital image correlation was used to assess strain distribution, confirm gauge section loading, and interpret failure locations. The results demonstrate how specimen geometry affects the accuracy of measured tensile strength and, consequently, the Weibull reliability distribution used for design and qualification. These findings support improved testing practices, defensible strength distributions, and reliable qualification and deployment of graphite components for extreme nuclear reactor environments. |