| Abstract Scope |
The origin of symmetric circular pits on iron surfaces remains insufficiently explained by acidity-based mechanisms alone, particularly under supercritical conditions where coffee-ring-like corrosion-product bands develop. Here, using steel exposed to CO₂–H₂O as a model system, we combine microscopy and spectroscopy with molecular dynamics, ab initio molecular dynamics, and finite-element simulations to show that localized corrosion is governed by phase-dependent interfacial wetting. As CO₂ transitions from gaseous to supercritical, its interfacial layer becomes denser, more ordered, and less mobile, increasing contact-line pinning of droplets on metal surfaces. This pinned geometry creates confined microenvironments, induces droplet-scale flow, and drives evaporation-mediated solute redistribution. Consequently, FeCO₃ preferentially accumulates at the droplet rim, while oxide products form at the pit bottom. Similar morphology transitions across steels support a phase-to-pattern framework. These findings identify interfacial wetting and droplet mobility as direct controls of localized corrosion and suggest mitigation strategies based on manipulating droplet attachment and transport. |